Equipment may use keypad access to control ignition and prevent unauthorized use. Follow the steps below to start your machine using your assigned keycode.
Quick Start (Most Common Setup)
Pull out all E-Stop buttons.
Enter your assigned code.
Press ENTER.
Press START (if available).
If the machine does not start, check the LED indicators below.
Where to Find Your Keycode
Your keycode is assigned when the rental begins.
You can find it:
In the on-rent email sent to the rental order creator
In T3 on the Rentals page
By creating a custom keycode in T3 (see Creating an Access Keycode)
Starting Equipment by Keypad Type
Identify your keypad layout below and follow the matching instructions.
Keypads with ENTER Only
If your keypad looks like this:
To Start
Pull out all E-Stop buttons.
Enter your assigned code.
Press and hold ENTER to turn the ignition on.
LED Indicators
Status | LED Behavior |
Button press | Blue LED 2 |
Invalid code | Flashing Red LED 1 |
Valid code | Green LED 4 |
Keypad stalled | Flashing Red LED 1 |
Lost communication | Flashing LED 3 |
Keypads with START and ENTER
If your keypad looks like this:
To Start
Enter the assigned code.
Press ENTER.
Press START.
LED Indicators
Status | LED Behavior |
Button press | Blue LED 2 |
Invalid code | Flashing Red LED 1 |
Valid code | Solid Green LED 4 + Solid Blue LED 2 (5-minute timeout) |
START held once | Solid Blue LED 2 + Solid Green LED 4 (no timeout) |
START pressed | Solid Green LED 2 + Solid Green LED 4 (no timeout) |
Keypad stalled | Flashing Red LED 1 |
Lost communication | Flashing LED 3 |
Keypads with GRND and PLTFM
If your keypad looks like this:
To Start in Ground Mode
Pull out all E-Stop buttons.
Enter the assigned code.
Press and hold ENTER.
To Switch to Platform Mode
Enter the assigned code.
Press PLTFM.
Press ENTER.
LED Indicators
Status | LED Behavior |
Button press | Blue LED 2 |
Invalid code | Flashing Red LED 1 |
Ground mode active | Solid Green LED 1 + Solid Green LED 2 |
Platform mode active | Solid Green LED 2 + Solid Green LED 4 |
Keypad stalled | Flashing Red LED 1 |
Lost communication | Flashing LED 3 |
Keypads with GLOW
If your keypad looks like this:
To Start
Enter the assigned code.
Press ENTER.
If Amber LED 1 illuminates, press GLOW for 10–20 seconds.
Press START.
LED Indicators
Status | LED Behavior |
Button press | Blue LED 2 |
Invalid code | Flashing Red LED 1 |
Valid code | Solid Yellow LED 1 + Solid Yellow LED 2 + Solid Green LED 4 |
GLOW held | Solid Green LED 1 + Solid Blue LED 2 + Solid Green LED 4 |
START pressed | Solid Green LED 2 + Solid Green LED 4 (no timeout) |
Keypad stalled | Flashing Red LED 1 |
Lost communication | Flashing LED 3 |
Turning the Machine Off
Press OFF on the keypad
orUse the E-Stop buttons
Important: If the E-Stop button is pulled out, the ignition remains on and the battery may drain.
Troubleshooting
Machine does not start
Confirm all E-Stops are pulled out.
Confirm the code was entered correctly.
Check LED behavior above.
Flashing Red LED
Invalid code entered.
Re-enter the code carefully.
Flashing LED 3
Lost communication.
Contact support.